The goal of this study was to determine how showerhead blowing on a turbine vane leading edge affects of the performance of film cooling jets farther downstream. An emphasis was placed on measurements above the surface, i.e., flow visualization, thermal field, and velocity field measurements. The film cooling performance on the pressure side of a simulated turbine vane, with and without showerhead blowing, was examined. Results presented in this paper are for low mainstream turbulence; high mainstream turbulence effects are presented in the companion paper. At the location of the pressure side row of holes, the showerhead coolant extended a distance of about from the surface is the coolant hole diameter). The pressure side was found to be subjected to high turbulence levels caused by the showerhead injection. Results indicate a greater dispersion of the pressure side coolant jets with showerhead flow due to the elevated turbulence levels.
Skip Nav Destination
Article navigation
October 2002
Technical Papers
Evaluation of Pressure Side Film Cooling With Flow and Thermal Field Measurements—Part I: Showerhead Effects
J. Michael Cutbirth,
J. Michael Cutbirth
William B. Morgan Large Cavitation Channel, Naval Surface Warfare Center, Carderock Division, Memphis, TN 38113
Search for other works by this author on:
David G. Bogard
David G. Bogard
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
Search for other works by this author on:
J. Michael Cutbirth
William B. Morgan Large Cavitation Channel, Naval Surface Warfare Center, Carderock Division, Memphis, TN 38113
David G. Bogard
Mechanical Engineering Department, University of Texas at Austin, Austin, TX 78712
Contributed by the International Gas Turbine Institute and presented at the International Gas Turbine and Aeroengine Congress and Exhibition, Amsterdam, The Netherlands, June 3–6, 2002. Manuscript received by the IGTI, November 2, 2001. Paper No. 2002-GT-30174. Review Chair: E. Benvenuti.
J. Turbomach. Oct 2002, 124(4): 670-677 (8 pages)
Published Online: November 7, 2002
Article history
Received:
November 2, 2001
Online:
November 7, 2002
Citation
Cutbirth, J. M., and Bogard, D. G. (November 7, 2002). "Evaluation of Pressure Side Film Cooling With Flow and Thermal Field Measurements—Part I: Showerhead Effects ." ASME. J. Turbomach. October 2002; 124(4): 670–677. https://doi.org/10.1115/1.1504441
Download citation file:
Get Email Alerts
Related Articles
Evaluation of Pressure Side Film Cooling With Flow and Thermal Field Measurements—Part II: Turbulence Effects
J. Turbomach (October,2002)
Three Component Velocity Field Measurements in the Stagnation Region of a Film Cooled Turbine Vane
J. Turbomach (July,2002)
Thermal Field and Flow Visualization Within the Stagnation Region of
a Film-Cooled Turbine Vane
J. Turbomach (April,2002)
Film Cooling of a Cylindrical Leading Edge With Injection Through Rows of Compound-Angle Holes
J. Heat Transfer (August,2001)
Related Proceedings Papers
Related Chapters
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
A Computational Assessment of Gas Jets in a Bubbly Co-Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Assessment of Remote Cavitation Detection Methods with Flow Visualization in a Full Scale Francis Turbine
Proceedings of the 10th International Symposium on Cavitation (CAV2018)