A two-phase natural circulation cooling has been proposed to remove melted core decay heat by external core catcher cooling system during sever accident scenario. In this paper, two types of the core catcher cooling loops, one with heated loop and the other adiabatic loop simulated with air water system are analytically studied. First, a scaling analysis was carried out for natural circulation flow in a closed loop. Based on the scaling analyses, simulation of two-phase natural circulation is carried out both for air–water and steam–water system in an inclined rectangular channel. The heat flux corresponding to the decay heat is simulated with steam generation rate or air flux into the test section to produce equivalent flow quality and void fraction. Design calculations were carried out for typical core catcher design to estimate the expected natural circulation rates. The natural circulation flow rate and two-phase pressure drop were obtained for different heat inputs or equivalent air injection rates expressed as void fraction for a select downcomer pipe size. These results can be used to scale a steam water system using scaling consideration presented. The results indicate that the air–water and steam water system show similar flow and pressure drop behavior.

References

1.
Song
,
J. H.
,
Kim
,
S. B.
, and
Kim
,
H. D.
,
2000
, “
An Analysis of Natural Circulation Cooling of a Reactor Vessel During Severe Accidents by RELAP5/MOD3 Computer Code
,”
Proceedings of the Korean Nuclear Society Spring Meeting
, Kori, Korea, pp.
1
10
.
2.
Song
,
J. H.
,
Kim
,
S. B.
, and
Kim
,
H. D.
,
2002
, “
Analysis of External Cooling of the Reactor Vessel During Severe Accidents
,”
Nucl. Technol.
,
138
(
1
), pp.
79
89
.
3.
Rempe
,
J. L.
,
Suh
,
K. Y.
,
Cheung
,
F. B.
, and
Kim
,
S. B.
,
2003
, “
In-Vessel Retention Strategy for High Power Reactors
,” Final Report, Idaho National Engineering and Environmental Laboratory, Report No. INEEL/EXT-04-02561.
4.
Ha
,
K. S.
,
Park
,
R. J.
,
Song
,
J. H.
,
Kim
,
J. T.
, and
Cheung
,
F. B.
,
2004
, “
A Non-Heating Experimental Study on the Two-Phase Natural Circulation Through the Annular Gap Between Reactor Vessel and Insulation Under External Vessel Cooling
,” ICAPP'04, Pittsburgh, PA, June 13–17, pp.
1721
1728
.
5.
Farmer
,
M. T.
,
Kilsdonk
,
D. J.
, and
Aeschlimann
,
R. W.
,
2009
, “
Corium Coolability Under Ex-Vessel Accident Conditions for LWRs
,”
Nucl. Eng. Technol.
,
41
(
5
), pp.
575
602
.10.5516/NET.2009.41.5.575
6.
Zhong
,
H.
,
2011
, “
A Study on the Coolability of Ex-Vessel Corium by Late Top Water Flooding
,” M.S. thesis, Royal Institute of Technology, Stockholm, Sweden.
7.
Kukhtevich
,
I. V.
,
Bezlepkin
,
V. V.
,
Granovskii
,
V. S.
,
Bechta
,
S. V.
, and
Gusarov
,
V. V.
,
2001
, “
The Concept of Localization of the Corium Melt in the Ex-Vessel Stage of a Severe Accident at a Nuclear Power Station With a VVER-1000 Reactor
,”
Therm. Eng.
,
48
(9), pp.
699
706
.
8.
Fisher
,
M.
,
2004
, “
The Severe Accident Mitigation Concept and the Design Measures for Core Melt Retention of the European Pressurized Re-Actor
,”
Nucl. Eng. Des.
,
230
(1–3), pp.
169
180
.10.1016/j.nucengdes.2003.11.034
9.
Song
,
J. H.
,
Ha
,
K. S.
,
Park
,
R. J.
,
Kim
,
J. T.
, and
Cheung
,
F. B.
,
2011
, “
A Core Catcher Design for the Advanced Light Water Reactor
,”
Proceedings of the International Conference on Advanced Nuclear Power Plants (ICAPP)
, Nice, France.
10.
Batchelor
,
G. K.
,
1987
, “
The Stability of a Large Gas Bubble Rising Through Liquid
,”
J. Fluid Mech.
,
184
(1), pp.
399
422
.10.1017/S0022112087002945
11.
Kataoka
,
I.
, and
Ishii
,
M.
,
1987
, “
Drift Flux Model for Large Diameter Pipe and New Correlation for Pool Void Fraction
,”
Int. J. Heat Mass Transfer
,
30
(9), pp.
1927
1939
.10.1016/0017-9310(87)90270-5
12.
Ishii
,
M.
,
Revankar
,
S. T.
,
Leonardi
,
T.
,
Dowlati
,
R.
,
Bertodano
,
M. L.
,
Babelli
,
I.
,
Wang
,
W.
,
Pokharna
,
H.
,
Ransom
,
V. H.
, R.
Viskanta
,
R.
, and
Han
,
J. T.
,
1998
, “
The Three-Level Scaling Approach With Application to the Purdue University Multi-Dimensional Integral Test Assembly (PUMA)
,”
Nucl. Eng. Des.
,
186
(
1–2
), pp.
177
211
.10.1016/S0029-5493(98)00222-2
13.
Ishii
,
M.
, and
Katoka
,
I.
,
1984
, “
Scaling of Laws for Thermal-Hydraulic System Under Single Phase and Two-Phase Natural Circulation
,”
Nuc. Eng. Des.
,
81
, pp.
411
425
.10.1016/0029-5493(84)90287-5
14.
Zuber
,
N.
, and
Findlay
,
J.
,
1965
, “
Average Volumetric Concentration in Two-Phase Systems
,”
ASME J. Heat Transfer
,
87
(4), pp.
453
468
.10.1115/1.3689137
15.
Awad
,
M. M.
, and
Muzychka
,
Y. S.
,
2004
, “
A Simple Two-Phase Frictional Multiplier Calculation Method
,”
Proceedings of the IPC 2004 International Pipeline Conference (IPC04-0721)
, Calgary, AB, Canada, Oct. 4–8, pp.
1
9
.
16.
Churchill
,
S. W.
,
1977
, “
Friction Factor Equation Spans All Fluid Flow Regimes
,”
Chem. Eng.
,
84
(
24
), pp.
91
92
.
17.
Sonnenburg
,
H. G.
,
1989
, “
Full-Range Drift-Flux Model Base on the Combination of Drift-Flux Theory With Envelope Theory
,”
Proceedings of the Nuclear Reactor Thermal Hydraulics NURETH-4
, Vol.
2
, pp.
1003
1009
.
18.
Franca
,
F.
, and
Lahey
,
R. T.
, Jr.
,
1992
, “
The Use of Drift-Flux Techniques for the Analysis of Horizontal Two-Phase Flows
,”
Int. J. Multiphase Flow
,
18
(6), pp.
787
801
.10.1016/0301-9322(92)90059-P
You do not currently have access to this content.