Using solar energy for space heating is an efficient and simply way to satisfy the energy demands of buildings. In this study, a typical office building is selected as a case model to obtain indoor air temperature characteristics with dual heat storage devices. By analyzing our solar heating system, a mathematical model of the system working process is set up. Using the software matlab/simulink for simulation, the indoor air temperature characteristics in 1 day are obtained. Simulation and experimental results show good consistency. And using the mathematical model, the storage tank size is optimized to search for the minimum size for the fixed building. Based on our analysis, the optimum ratio of storage tank A volume and collector field area is 0.11 m. This research can be a good reference for the design of the solar heating system.

References

1.
Chang
,
C.
,
Zhu
,
N.
,
Yang
,
K.
, and
Yang
,
F.
,
2018
, “
Data and Analytics for Heating Energy Consumption of Residential Buildings: The Case of a Severe Cold Climate Region of China
,”
Energy Build.
,
172
, pp.
104
115
.
2.
Diao
,
L. Q.
,
Sun
,
Y. J.
,
Chen
,
Z. J.
, and
Chen
,
J. Y.
,
2017
, “
Modeling Energy Consumption in Residential Buildings: A Bottom-Up Analysis Based on Occupant Behavior Pattern Clustering and Stochastic Simulation
,”
Energy Build.
,
147
, pp.
47
66
.
3.
Kacan
,
E.
,
Ulgen
,
K.
, and
Kaçan
,
E.
,
2015
, “
What is the Effect of Optimum Independent Parameters on Solar Heating Systems?
,”
Energ. Convers. Manage.
,
105
, pp.
103
117
.
4.
Jing
,
O. L.
,
Bashir
,
M. J. K.
, and
Kao
,
J. J.
,
2015
, “
Solar Radiation Based Benefit and Cost Evaluation for Solar Water Heater Expansion in Malaysia
,”
Renewable Sustainable Energy Rev.
,
48
, pp.
328
335
.
5.
Yan
,
C. C.
,
Wang
,
S. W.
,
Ma
,
Z. J.
, and
Shi
,
W. X.
,
2015
, “
A Simplified Method for Optimal Design of Solar Water Heating Systems Based on Life-Cycle Energy Analysis
,”
Renew Energy
,
74
, pp.
271
278
.
6.
Date
,
A.
,
Date
,
A.
,
Dixon
,
C.
, and
Akbarzadeh
,
A.
,
2014
, “
Theoretical and Experimental Study on Heat Pipe Cooled Thermoelectric Generators With Water Heating Using Concentrated Solar Thermal Energy
,”
Sol. Energy
,
105
, pp.
656
668
.
7.
Ntsaluba
,
S.
,
Zhu
,
B.
, and
Xia
,
X. H.
,
2016
, “
Optimal Flow Control of Forced Circulation Solar Water Heating System With Energy Storage Units and Connecting Pipes
,”
Renew Energy
,
89
, pp.
108
124
.
8.
Comakli
,
K.
,
Cakir
,
U.
,
Kaya
,
M.
, and
Bakirci
,
K.
,
2012
, “
The Relation of Collector and Storage Tank Size in Solar Heating Systems
,”
Energ. Convers. Manage.
,
63
, pp.
112
117
.
9.
Chaabane
,
M.
,
Mhiri
,
H.
, and
Bournot
,
P.
,
2014
, “
Thermal Performance of an Integrated Collector Storage Solar Water Heater (ICSSWH) With Phase Change Materials (PCM)
,”
Energ. Convers. Manage.
,
78
, pp.
897
903
.
10.
Rodríguez-Hidalgo
,
M. C.
,
Rodríguez-Aumente
,
P. A.
,
Lecuona
,
A.
,
Legrand
,
M.
, and
Ventas
,
R.
,
2012
, “
Domestic Hot Water Consumption vs. Solar Thermal Energy Storage: The Optimum Size of the Storage Tank
,”
Appl. Energ.
,
97
, pp.
897
906
.
11.
Bracamonte
,
J.
,
2017
, “
Effect of the Transient Energy Input on Thermodynamic Performance of Passive Water-in-Glass Evacuated Tube Solar Water Heaters
,”
Renew. Energy
,
105
, pp.
689
701
.
12.
Krishnavel
,
V.
,
Karthick
,
A.
, and
Murugavel
,
K. K.
,
2014
, “
Experimental Analysis of Concrete Absorber Solar Water Heating System
,”
Energy Build.
,
84
, pp.
501
505
.
13.
Chong
,
K. K.
,
Chay
,
K. G.
, and
Chin
,
K. H.
,
2012
, “
Study of a Solar Water Heater Using Stationary V-Trough Collector
,”
Renew. Energy
,
39
(
1
), pp.
207
215
.
14.
Hossain
,
M. S.
,
Saidur
,
R.
,
Fayaz
,
H.
,
Rahim
,
N. A.
,
Islam
,
M. R.
,
Ahamed
,
J. U.
, and
Rahman
,
M. M.
,
2011
, “
Review on Solar Water Heater Collector and Thermal Energy Performance of Circulating Pipe
,”
Renew. Sust. Energ. Rev.
,
15
(
8
), pp.
3801
3812
.
15.
Jamar
,
A.
,
Majid
,
Z. A. A.
,
Azmi
,
W. H.
,
Norhafana
,
M.
, and
Razak
,
A. A.
,
2016
, “
A Review of Water Heating System for Solar Energy Applications
,”
Int. Commun. Heat Mass
,
76
, pp.
178
187
.
16.
Gao
,
Y.
,
Fan
,
R.
,
Zhang
,
X. Y.
,
An
,
X. J.
,
Wang
,
M. X.
,
Gao
,
Y. K.
, and
Yu
,
Y.
,
2014
, “
Thermal Performance and Parameter Analysis of a U-Pipe Evacuated Solar Tube Collector
,”
Sol. Energy
,
107
, pp.
714
727
.
17.
Ibrahim
,
O.
,
Faurdon
,
F.
,
Younes
,
R.
, and
Louahlia-Gualous
,
H.
,
2014
, “
Review of Water-Heating Systems: General Selection Approach Based on Energy and Environmental Aspects
,”
Build. Environ.
,
72
, pp.
259
286
.
18.
Morrison
,
G. L.
,
Budihardio
,
I.
, and
Behnia
,
M.
,
2004
, “
Water-In-Glass Evacuated Tube Solar Water Heaters
,”
Sol. Energy
,
76
, pp.
135
140
.
19.
Shah
,
L. J.
, and
Furbo
,
S.
,
2007
, “
Theoretical Flow Investigations of an All Glass Evacuated Tubular Collector
,”
Sol. Energy
,
81
, pp.
822
828
.
20.
Budihardjo
,
I.
, and
Morrison
,
G. L.
,
2009
, “
Performance of Water-In-Glass Evacuated Tube Solar Water Heaters
,”
Sol. Energy
,
83
, pp.
49
56
.
21.
Han
,
H.
,
Kim
,
J. T.
, and
Ahn
,
H. T.
,
2008
, “
A Three-Dimensional Performance Analysis of All-Glass Vacuum Tubes With Coaxial Fluid Conduit
,”
Int. Commun. Heat Transfer
,
35
, pp.
589
596
.
22.
Liu
,
Z. J.
,
Li
,
H.
,
Liu
,
K. J.
,
Yu
,
H. C.
, and
Cheng
,
K. W.
,
2017
, “
Design of High-Performance Water-In-Glass Evacuated Tube Solar Water Heaters by a High-Throughput Screening Based on Machine Learning: A Combined Modeling and Experimental Study
,”
Sol. Energy
,
142
, pp.
61
67
.
23.
Ferrer
,
P. A. F.
,
2017
, “
Average Economic Performance of Solar Water Heaters for Low Density Dwellings Across South Africa
,”
Renew. Sust. Energ. Rev.
,
76
, pp.
507
515
.
24.
Qiu
,
S. F.
,
Ruth
,
M.
, and
Ghosh
,
S.
,
2015
, “
Evacuated Tube Collectors: A Notable Driver Behind the Solar Water Heater Industry in China
,”
Sust. Energ. Rev.
,
47
, pp.
580
588
.
25.
Kacan
,
E.
,
2015
, “
Exergetic Optimization of Basic System Components for Maximizing Exergetic Efficiency of Solar Combisystems by Using Response Surface Methodology
,”
Energy Build
,
91
, pp.
65
82
.
26.
Kacan
,
E.
, and
Ulgen
,
K.
,
2012
, “
Energy Analysis of Solar Combisystems in Turkey
,”
Energ. Convers. Manage.
,
64
, pp.
378
386
.
27.
Deng
,
S.
,
Dai
,
Y. J.
, and
Wang
,
R. Z.
,
2013
, “
Performance Optimization and Analysis of Solar Combi-System With Carbon Dioxide Heat Pump
,”
Sol. Energy
,
98
, pp.
212
225
.
28.
ANSI/ASHRAE Standard 55-2004, Thermal Environmental Conditions for Human Occupancy, American Society of Heating, Refrigerating and Air-Conditioning Engineers Inc, USA, 2004. https://www.ashrae.org/standards-research-technology
29.
International Organization for Standardization, Moderate Thermal Environments—Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort, in: ISO 7730, International Organization for Standardization, 1994.
30.
Klein
,
S. A.
,
Beckman
,
W. A.
, and
Duffie
,
J. A.
,
1976
, “
A Design Procedure for Solar Heating Systems
,”
Sol. Energy
,
18
, pp.
113
27
.
31.
Kabeel
,
A. E.
,
Khalil
,
A.
,
Elsayed
,
S. S.
, and
Alatyar
,
A. M.
,
2015
, “
Modified Mathematical Model for Evaluating the Performance of Water-in-Glass Evacuated Tube Solar Collector Considering Tube Shading Effect
,”
Energy
,
89
, pp.
24
34
.
32.
Wu
,
X. Z.
,
Liu
,
Y. J.
,
Liu
,
G. L.
,
Wang
,
F. H.
, and
Wang
,
Z. H.
,
2017
, “
Effect of Supply Air Temperature on Indoor Thermal Comfort in a Room With Radiant Heating and Mechanical Ventilation
,”
Energy Proc.
,
121
, pp.
206
213
.
33.
Shen
,
C.
,
He
,
Y. L.
,
Liu
,
Y. W.
, and
Tao
,
W. Q.
,
2008
, “
Modelling and Simulation of Solar Radiation Data Processing With Simulink
,”
Simul. Model. Pract. Theory
,
16
, pp.
721
735
.
34.
Ghaddar
,
N. K.
,
1994
, “
Stratified Storage Tank Influence on Performance of Solar Water Heating System Tested in Beirut
,”
Renew. Energy
,
4
, pp.
911
925
.
You do not currently have access to this content.