Data centers are facilities that primarily contain electronic equipment used for data processing, data storage, and communications networking. Regardless of their use and configuration, most data centers are more energy intensive than other buildings. The continuous operation of information technology equipment and power delivery systems generates a significant amount of heat that must be removed from the data center for the electronic equipment to operate properly. Since data centers spend up to half their energy on cooling, cooling systems becomes a key factor for energy consumption reduction strategies and alternatives in the data centers. This paper presents a theoretical analysis of an absorption chiller driven by solar thermal energy as cooling plant alternative for data centers. Source primary energy consumption is used to compare the performance of different solar cooling plants with a standard cooling plant. The solar cooling plants correspond to different combinations of solar collector arrays and thermal storage tank, with a boiler as source of energy to ensure continuous operation of the absorption chiller. The standard cooling plant uses an electric chiller. Results suggest that the solar cooling plant with flat-plate solar collectors is a better option over the solar cooling plant with evacuated-tube solar collectors. However, although solar cooling plants can decrease the primary energy consumption when compared with the standard cooling plant, the net present value of the cost to install and operate the solar cooling plants are higher than the one for the standard cooling plant.

References

1.
U.S. Environmental Protection Agency, Energy Start Program, 2007, “Report to Congress on Server and Data Center Energy Efficiency,” http://www.energystar.gov/index.cfm?=prod_development.server_efficiency_studyhttp://www.energystar.gov/index.cfm?=prod_development.server_efficiency_study
2.
Judge
,
J.
,
Pouchet
,
J.
,
Ekbote
,
A.
, and
Dixit
,
S.
, 2008,
“Reducing Data Center Energy Consumption,”
ASHRAE J.
,
50
(
11
), pp.
14
26
.
3.
Koomey
,
J. G.
, 2004,
“Data Center Power Use: A Review of the Historical Data,”
Proceedings of the IBM Austin Conference on Energy-Efficient Design Austin, TX. http://hightech.lbl.gov/presentations/ibmdatacentertalk040302.pdfhttp://hightech.lbl.gov/presentations/ibmdatacentertalk040302.pdf
4.
Beaty
,
D.
, and
Davidson
,
T.
, 2003,
“New Guideline for Data Center Cooling,”
ASHRAE J.
,
45
(
12
), pp.
28
34
.
5.
Belady
,
C.
, and
Beaty
,
D.
, 2005,
“Data Centers, Roadmap for Datacom Cooling,”
ASHRAE J.
,
47
(
12
), pp.
52
55
.
6.
Bean
,
J.
, and
Dunlap
,
K.
, 2008,
“Energy-Efficient Data Centers, a Close-Coupled Row Solution,”
ASHRAE J.
,
50
(
10
), pp.
34
42
.
7.
Pacific Gas and Electric Company, 2006,
“High Performance Data Centers, A Design Guidelines Sourcebook,”
http://hightech.lbl.gov/documents/data_centers/06_datacenters-pge.pdfhttp://hightech.lbl.gov/documents/data_centers/06_datacenters-pge.pdf
8.
Fredslund
,
K.
,
Isleifsson
,
F.
,
Andersen
,
J. J.
,
Zamboni
,
M.
, and
Pantchenko
,
O.
, 2009 “Green Data Center Cooling,” Report of the Local Renewable Energy Summer Research program. http://www.local-re.org/~localre/index.php/downloads/2009-project-reports/56-green-data-center-cooling-reporthttp://www.local-re.org/~localre/index.php/downloads/2009-project-reports/56-green-data-center-cooling-report
9.
Sparber
,
W.
,
Napolitano
,
A.
, and
Melograno
,
P.
, 2007,
“Overview on World Wide Installed Solar Cooling Systems,”
Proceedings of the 2nd International Conference Solar Air Conditioning
,
Tarragona
,
Spain
, http://www.iea-shc.org/publications/downloads/task38-Overview.pdfhttp://www.iea-shc.org/publications/downloads/task38-Overview.pdf
10.
U.S. Department of Energy, Energy Efficiency and Renewable Energy Office, Building Technology Program, energyplus. http://apps1.eere.energy.gov/buildings/energyplus/http://apps1.eere.energy.gov/buildings/energyplus/
11.
ASHRAE, 2007,
“Data Processing and Electronic Office Areas,”
Handbook HVAC Applications, Chap. 17.
15.
Government of California, Green California Project, LCCA Model, http://www.green.ca.gov/LCCA/model.htmhttp://www.green.ca.gov/LCCA/model.htm
16.
RETScreen International, RETScreen Clean Energy Project Analysis Software, http://www.retscreen.net/ang/home.phphttp://www.retscreen.net/ang/home.php
You do not currently have access to this content.