The development of OpenFES hardware presented in this paper involved a closed-loop functional electrical stimulation (FES) system that could be assembled from off-the-shelf parts in India. The state-of-the-art biosignal-based control strategies could be evaluated in a clinical research setting using the familiar development environment of MATLAB/SIMULINK (The Mathworks). This hardware was developed primarily for a rehabilitation research center where students from an engineering and medical school could use it as a testbed for clinical research. It is envisioned that the design of a working prototype would be available after thorough testing at http://robo4rehab.wikispaces.com/OpenFES so that it can be further enhanced in an open-source setting. The command source selected for modulating/triggering the electrical stimulation was electromyogram (EMG), which is the recording of the bioelectrical signal generated at the cell membrane of contracting muscle fibers. The FES controller was implemented in an xPC target (The Mathworks) real-time kernel, running on a single board computer where the stimulation pattern, i.e., the temporal pattern of current pulses, was computed online based on the surface EMG patterns. The stimulation parameters were passed to a dsPIC33F microcontroller (Microchip, India) driven voltage controlled current source (VCCS) via a universal asynchronous receiver/transmitter (UART). The VCCS consisted of a coupled transconductance amplifier in series with precharged capacitors. The biphasic stimulation waveform was obtained with an analog switch that switched to reverse the polarity of the surface electrodes. The input stage for surface EMG consisted of an instrumentation amplifier with an anti-aliasing filter made of switched-capacitor (recording capacitor) banks. The dry surface EMG electrodes had buffer op-amps to provide high input impedance. A dsPIC33F microcontroller (Microchip, India) in the input/output (I/O) stage coordinated the switching of the stimulating capacitors with the recording capacitors in order to reject the stimulation artifact. The control software ran on the xPC target and delivered the stimulation parameters via UART to the dsPIC33F microcontroller (Microchip, India). The controller specifications are as follows: (1) Communications: xPC target is a battery powered stand-alone FES controller, communicating with the slave microprocessor in the input/output stages via UART. (2) FES controller: PC/104 single board computer (Advantech Co., PCM-3355) running xPC target kernel (The Mathworks). (3) PC/104 CPU: 366 MHz ×86 (AMD Geode processor). (4) Display: LCD ( at 18 bpp TFT) or CRT ( at 24 noninterlaced). (5) Stimulation pulse-width range: 1–255 ms. (6) Stimulation amplitude range: 0–100 mA (16 bit analog output with voltage controlled current source). (7) Stimulation frequency range: up to 30 Hz. (8) I/O channels (Sensoray, model 526): 4 AO (16 bit), 8 DIO, and 8 AI (16 bit). (9) Channel offset: 1000 Hz. (10) Analog to digital conversion for EMG: 16 bit. (11) Maximum signal amplitude: about 10 mV (peak to peak). (12) Minimum signal amplitude: about 1 mV (peak to peak), i.e., the noise floor should preferably be lower. (13) Signal to noise ratio.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
OpenFES: Development of an Open-Source EMG-Triggered Functional Electrical Stimulation Controller for Physical Therapy
Anirban Dutta,
Anirban Dutta
Robotics for Rehabilitation Research Center
Search for other works by this author on:
Nasir U. Ahmed
Nasir U. Ahmed
b2u Technology Inc.
Search for other works by this author on:
Anirban Dutta
Robotics for Rehabilitation Research Center
Nasir U. Ahmed
b2u Technology Inc.
J. Med. Devices. Jun 2010, 4(2): 027531 (1 pages)
Published Online: August 11, 2010
Article history
Published:
August 11, 2010
Citation
Dutta, A., and Ahmed, N. U. (August 11, 2010). "OpenFES: Development of an Open-Source EMG-Triggered Functional Electrical Stimulation Controller for Physical Therapy." ASME. J. Med. Devices. June 2010; 4(2): 027531. https://doi.org/10.1115/1.3443736
Download citation file:
1,802
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
The Therapress 1600i: Accelerating Knee Rehabilitation
J. Med. Devices (June,2009)
Nonlinear Smooth Orthogonal Decomposition of Kinematic Features of Sawing Reconstructs Muscle Fatigue Evolution as Indicated by Electromyography
J Biomech Eng (March,2011)
Electromyogram-Triggered Functional Electrical Stimulation-Assisted Walking After Partial Paralysis
J. Med. Devices (June,2008)
Gait Initiation With Electromyographically Triggered Electrical Stimulation in People With Partial Paralysis
J Biomech Eng (August,2009)
Related Proceedings Papers
Related Chapters
Classification of Electromyogram Signal for Control of Robotic Gripper
International Conference on Computer Engineering and Technology, 3rd (ICCET 2011)
A Review for Feature Extraction of EMG Signal Processing
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)
Modeling and Classification for Uterine EMG Signals Using Autoregressive Model
Intelligent Engineering Systems through Artificial Neural Networks, Volume 16