According to the American Heart Association, approximately 166,200 out-of-hospital cardiac arrests occur each year. It is estimated that a victim's chances of survival are reduced by 7-10 percent for every minute that passes without treatment. Obviously, time is very critical in such situations. In most cardiac arrest cases, there is little to no warning to the victim that their heart has stopped and thus no time to notify others that emergency care is immediately required. To help alert the victim and others that a cardiac arrest episode has occurred, an ambulatory alarm and notification system has been built for individuals at high risk of cardiac arrest. The cardiac arrest alert system uses a ring-style photoplethysmograph that is connected to an armband unit which performs signal processing and wireless transmission and possesses an audible alarm. A wristband interface provides visual and tactile warnings, a reset button and a threshold adjuster. If the user's heart rate goes outside the preset range or is not detected by the system, a visual and tactile warning notifies the user of the situation. If the device is not reset or the problem not rectified within several seconds, the device then goes into full activation mode and sounds a loud alarm to notify nearby individuals who may be able to provide emergency assistance to the user. In full activation mode, the device also wirelessly transmits a signal to a central unit that, when signaled, automatically calls 911 and plays a pre-recorded message that states the incident and specifies the location. An additional phone number can also be stored so that another notification call is automatically performed. The central unit has a speaker so that the notification message is locally audible as well. In emergency situations, the cardiac arrest alert system will provide a life-saving service by rapidly alerting the user as well as nearby individuals and emergency respondents who can provide immediate assistance.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Cardiac Arrest Alert System
M. Schroeder,
M. Schroeder
North Dakota State University
, Fargo, ND USA
Search for other works by this author on:
E. Alvarez,
E. Alvarez
North Dakota State University
, Fargo, ND USA
Search for other works by this author on:
M. Steele,
M. Steele
North Dakota State University
, Fargo, ND USA
Search for other works by this author on:
P. Malhotra,
P. Malhotra
North Dakota State University
, Fargo, ND USA
Search for other works by this author on:
M. Mbipeh
M. Mbipeh
North Dakota State University
, Fargo, ND USA
Search for other works by this author on:
M. Schroeder
North Dakota State University
, Fargo, ND USA
E. Alvarez
North Dakota State University
, Fargo, ND USA
M. Steele
North Dakota State University
, Fargo, ND USA
P. Malhotra
North Dakota State University
, Fargo, ND USA
M. Mbipeh
North Dakota State University
, Fargo, ND USAJ. Med. Devices. Jun 2009, 3(2): 027532 (1 pages)
Published Online: July 9, 2009
Article history
Published:
July 9, 2009
Citation
Schroeder, M., Alvarez, E., Steele, M., Malhotra, P., and Mbipeh, M. (July 9, 2009). "Cardiac Arrest Alert System." ASME. J. Med. Devices. June 2009; 3(2): 027532. https://doi.org/10.1115/1.3147483
Download citation file:
820
Views
Get Email Alerts
Cited By
Context-Driven Design of a Laparoscopic Instrument Cleaner for Use in Rural Low-Resource Hospitals
J. Med. Devices (March 2025)
Controlled Ice Nucleation With a Sand-PDMS Film Device Enhances Cryopreservation of Mouse Preantral Ovarian Follicles
J. Med. Devices (December 2024)
Review of Blood and Fluid Warming Methods
J. Med. Devices (December 2024)
Related Articles
Variable Self-Optimizing Cochlear Model for Heart Murmur Detection/Classification
J. Med. Devices (June,2009)
Optical System Design of Laser-Based Stethoscope
J. Med. Devices (June,2011)
Separating Aortic Stenosis From Nornal Heart Decision Spaces Using a Quadratic Model
J. Med. Devices (June,2009)
Intra-Operative Pulse Oximetry
J. Med. Devices (June,2009)
Related Proceedings Papers
Related Chapters
Introduction
Modified Detrended Fluctuation Analysis (mDFA)
Micromachined 1-3 Composite Single Element Transducers
High Frequency Piezo-Composite Micromachined Ultrasound Transducer Array Technology for Biomedical Imaging
Computer-Aided Screening Program Management in Audiology and Cardiology
International Conference on Measurement and Control Engineering 2nd (ICMCE 2011)