Heat transfer rates were experimentally measured for laminar convection air flows in two-dimensional triangular enclosures with two side walls which were heated and cooled and an adiabatic bottom. Both local and overall heat transfer data were obtained by the use of a Wollaston prism schlieren interferometer. The angle between the two isothermal side walls was varied between 60 and 120 deg, which resulted in a variation in aspect ratio (enclosure height/base width) between 0.29 and 0.87, while the Grashof number was varied between 2.9 × 106 and 9.0 × 106. Results are compared to previously obtained isothermal inclined flat plate data and rectangular enclosure data. Present results agree with rectangular enclosure results. One deviation from local rectangular enclosure data was found in the apex regions of the triangular enclosures, where complex thermal and flow interactions occurred due to proximity of the two side walls.
Skip Nav Destination
Article navigation
Research Papers
The Measurement of Natural Convective Heat Transfer in Triangular Enclosures
R. D. Flack,
R. D. Flack
Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22901
Search for other works by this author on:
T. T. Konopnicki,
T. T. Konopnicki
Texas Instruments, Inc., Dallas, TX
Search for other works by this author on:
J. H. Rooke
J. H. Rooke
Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22901
Search for other works by this author on:
R. D. Flack
Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22901
T. T. Konopnicki
Texas Instruments, Inc., Dallas, TX
J. H. Rooke
Department of Mechanical and Aerospace Engineering, University of Virginia, Charlottesville, VA 22901
J. Heat Transfer. Nov 1979, 101(4): 648-654 (7 pages)
Published Online: November 1, 1979
Article history
Received:
July 26, 1978
Online:
August 11, 2010
Citation
Flack, R. D., Konopnicki, T. T., and Rooke, J. H. (November 1, 1979). "The Measurement of Natural Convective Heat Transfer in Triangular Enclosures." ASME. J. Heat Transfer. November 1979; 101(4): 648–654. https://doi.org/10.1115/1.3451051
Download citation file:
Get Email Alerts
Cited By
Related Articles
The Experimental Measurement of Natural Convective Heat Transfer in Rectangular Enclosures with Concentrated Energy Sources
J. Heat Transfer (May,1980)
Low-Velocity Heat Transfer to a Flat Plate in The Presence of a Corona Discharge in Air
J. Heat Transfer (February,1979)
Visualization of Convection at an Indoor Window Glazing With a Venetian Blind
J. Heat Transfer (August,2002)
Heat Transfer From an Isothermal Vertical Surface With Adjacent Heated Horizontal Louvers: Validation
J. Heat Transfer (December,2002)
Related Proceedings Papers
Related Chapters
Extended Surfaces
Thermal Management of Microelectronic Equipment
Extended Surfaces
Thermal Management of Microelectronic Equipment, Second Edition
A Novel Slow Light Mach-Zehnder Fiber Interferometer
International Conference on Instrumentation, Measurement, Circuits and Systems (ICIMCS 2011)