In this paper, an inverse problem is solved for estimating parameters of a steam-driven water–lithium bromide (LiBr) vapor absorption refrigeration system (VARS) using a differential evolution (DE)-based inverse approach. Initially, a forward model simulates the steady-state performance of the VARS at various operating temperatures and evaporator cooling loads (CLs). A DE-based inverse analysis is then performed to estimate the operating parameters taking VARS coefficient of performance (COP), CL, total irreversibility, and exergy efficiency as objective functions (one objective function at a time). DE-based inverse technique estimates the parameters within a very short period of elapsed time. Over 50 and 100 numbers of generations are sufficient for retrieval of COP and exergy efficiency, respectively, while it requires 150 generations for total irreversibility and CL. The study reveals that multiple combinations of parameters within a given range satisfy a particular objective function which serves as design guidelines in selecting appropriate operating parameters.
Skip Nav Destination
Article navigation
March 2016
Research-Article
Estimation of Operating Parameters of a Water–LiBr Vapor Absorption Refrigeration System Through Inverse Analysis
T. K. Gogoi
T. K. Gogoi
Department of Mechanical Engineering,
Tezpur University,
Napaam,
Tezpur 784028, India
e-mail: tapan_g@tezu.ernet.in
Tezpur University,
Napaam,
Tezpur 784028, India
e-mail: tapan_g@tezu.ernet.in
Search for other works by this author on:
T. K. Gogoi
Department of Mechanical Engineering,
Tezpur University,
Napaam,
Tezpur 784028, India
e-mail: tapan_g@tezu.ernet.in
Tezpur University,
Napaam,
Tezpur 784028, India
e-mail: tapan_g@tezu.ernet.in
1Corresponding author.
Contributed by the Advanced Energy Systems Division of ASME for publication in the JOURNAL OF ENERGY RESOURCES TECHNOLOGY. Manuscript received December 10, 2014; final manuscript received October 9, 2015; published online November 12, 2015. Assoc. Editor: Mansour Zenouzi.
J. Energy Resour. Technol. Mar 2016, 138(2): 022002 (16 pages)
Published Online: November 12, 2015
Article history
Received:
December 10, 2014
Revised:
October 9, 2015
Citation
Gogoi, T. K. (November 12, 2015). "Estimation of Operating Parameters of a Water–LiBr Vapor Absorption Refrigeration System Through Inverse Analysis." ASME. J. Energy Resour. Technol. March 2016; 138(2): 022002. https://doi.org/10.1115/1.4031833
Download citation file:
Get Email Alerts
Related Articles
Simulation and Experimental Analysis of a Solar Driven Absorption Chiller With Partially Wetted Evaporator
J. Sol. Energy Eng (February,2010)
Thermoeconomic Analysis of Novel Vapor Compression-Absorption Multi-Target-Temperature Cascade Refrigeration System
J. Thermal Sci. Eng. Appl (April,2023)
An Alternative Method for the Cooling of Power Microelectronics Using Classical Refrigeration
J. Electron. Packag (December,2008)
A Parametric Examination of the Factors Affecting the Performance of a Diffusion Absorption Refrigeration System
J. Thermal Sci. Eng. Appl (July,2022)
Related Chapters
Combined Cycle Power Plant
Energy and Power Generation Handbook: Established and Emerging Technologies
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Engineering and Physical Modeling of Power Plant Cooling Systems
Thermal Power Plant Cooling: Context and Engineering