Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-5 of 5
Keywords: design
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research-Article
J Biomech Eng. January 2025, 147(1): 011008.
Paper No: BIO-24-1170
Published Online: November 20, 2024
.... However, current testing devices compatible with magnetic resonance imaging (MRI) are often limited to uniaxial compression, often applying low loads, or loading individual tissues (instead of multiple), while more complex simulators do not facilitate MRI. Hence, in this work, we designed, built...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Design Innovation Paper
J Biomech Eng. March 2014, 136(3): 035002.
Paper No: BIO-13-1098
Published Online: February 13, 2014
... production or absorption across a broad range (from −5 to 21 J per step). These results support the use of robotic emulators during early stage assessment of proposed device functionalities and for scientific study of fundamental aspects of human–robot interaction. The design of simple, alternate end...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Design Innovations
J Biomech Eng. January 2010, 132(1): 015001.
Published Online: December 18, 2009
...Brian J. South; Nicholas P. Fey; Gordon Bosker; Richard R. Neptune Proper selection of prosthetic foot-ankle components with appropriate design characteristics is critical for successful amputee rehabilitation. Elastic energy storage and return (ESAR) feet have been developed in an effort...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Technical Briefs
J Biomech Eng. August 2009, 131(8): 084503.
Published Online: July 6, 2009
... at initial contact has been suggested to give rise to the ROL, and a repetitive, high ROL may lead to several disorders, including osteoarthritis. We present the design, development, and validation of a knee brace that provides feedback to the user during gait. The feedback consists of an auditory signal...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Publisher: ASME
Article Type: Research Papers
J Biomech Eng. April 2008, 130(2): 021009.
Published Online: March 28, 2008
... transmission. The accuracy of instrumented implants is restricted by their small size, varying modes of load transfer, and the accuracy of calibration. Aims of this study were to test with finite element studies design features to improve the accuracy, to develop simple but accurate calibration arrangements...