A spine is proven to be subjected to a follower load which is a compressive load of physiologic magnitude acting on the whole spine. The path of the follower load approximates the tangent to the curve of the spine in in vivo neutral standing posture. However, the specific path location of the follower load is still unclear. The aim of this study is to find out the most realistic location of the follower load path (FLP) for a lumbar spine in standing. A three-dimensional (3D) nonlinear finite element model (FEM) of lumbosacral vertebrae (L1-S1) with consideration of the calibrated material properties was established and validated by comparing with the experimental data. We show that the shape of the lumbosacral spine is strongly affected by the location of FLP. An evident nonlinear relationship between the FLP location and the kinematic response of the L1-S1 lumbosacral spine exists. The FLP at about 4 and 3 mm posterior to the curve connecting the center of the vertebral bodies delivers the most realistic location in standing for healthy people and patients having low back pains (LPBs), respectively. Moreover, the “sweeping” method introduced in this study can be applicable to all individualized FEM to determine the location of FLP.
Skip Nav Destination
Article navigation
March 2019
Research-Article
The Path to Deliver the Most Realistic Follower Load for a Lumbar Spine in Standing Posture: A Finite Element Study
Han Zhang,
Han Zhang
Shanghai Institute of Applied
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
Search for other works by this author on:
Weiping Zhu
Weiping Zhu
Shanghai Institute of Applied
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
e-mail: wpzhu@shu.edu.cn
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
e-mail: wpzhu@shu.edu.cn
Search for other works by this author on:
Han Zhang
Shanghai Institute of Applied
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
Weiping Zhu
Shanghai Institute of Applied
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
e-mail: wpzhu@shu.edu.cn
Mathematics and Mechanics,
Shanghai University,
Shanghai, 200072, China
e-mail: wpzhu@shu.edu.cn
1Corresponding author.
Manuscript received March 14, 2018; final manuscript received December 26, 2018; published online January 31, 2019. Assoc. Editor: Eric A. Kennedy.
J Biomech Eng. Mar 2019, 141(3): 031010 (10 pages)
Published Online: January 31, 2019
Article history
Received:
March 14, 2018
Revised:
December 26, 2018
Citation
Zhang, H., and Zhu, W. (January 31, 2019). "The Path to Deliver the Most Realistic Follower Load for a Lumbar Spine in Standing Posture: A Finite Element Study." ASME. J Biomech Eng. March 2019; 141(3): 031010. https://doi.org/10.1115/1.4042438
Download citation file:
Get Email Alerts
Optimal Control Formulation for Manual Wheelchair Locomotion Simulations: Influence of Anteroposterior Stability
J Biomech Eng (November 2023)
Related Articles
Application of the Finite Element Technique in the Design and Evaluation of the Artificial Facets for the Lumbar Spine
J. Med. Devices (June,2007)
Quantifying Variability in Lumbar L4-L5 Soft Tissue Properties for Use in Finite-Element Analysis
J. Verif. Valid. Uncert (September,2016)
A Finite Element Based Comparative Study of Lumbosacral Pedicle Screw Fixation and Artificial Disc Replacement
ASME J of Medical Diagnostics (August,2023)
Biomechanical Analysis of a Long-Segment Fusion in a Lumbar Spine—A Finite Element Model Study
J Biomech Eng (September,2018)
Related Proceedings Papers
Related Chapters
List of Commercial Codes
Introduction to Finite Element, Boundary Element, and Meshless Methods: With Applications to Heat Transfer and Fluid Flow
Data Tabulations
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Approximate Analysis of Plates
Design of Plate and Shell Structures